  Datasheet File OCR Text:
 Type
IPD060N03L G IPS060N03L G
IPF060N03L G IPU060N03L G
OptiMOS 3 Power-Transistor
TM
Product Summary V DS R DS(on),max ID 30 6 50 V m A
Features * Fast switching MOSFET for SMPS * Optimized technology for DC/DC converters * Qualified according to JEDEC for target applications * N-channel, logic level * Excellent gate charge x R DS(on) product (FOM) * Very low on-resistance R DS(on) * Avalanche rated * Pb-free plating
1)
IPD060N03L G Type * Avalanche rated * Pb-free plating; RoHS compliant
IPF060N03L G
IPS060N03L G
IPU060N03L G
Package Marking
PG-TO252-3 060N03L
PG-TO252-3-23 060N03L
PG-TO251-3-11 060N03L
PG-TO251-3 060N03L
Maximum ratings, at T j=25 C, unless otherwise specified Parameter Continuous drain current Symbol Conditions ID V GS=10 V, T C=25 C V GS=10 V, T C=100 C V GS=4.5 V, T C=25 C V GS=4.5 V, T C=100 C Pulsed drain current2) Avalanche current, single pulse 3) Avalanche energy, single pulse Reverse diode dv /dt Gate source voltage
1)
Value 50 50 50 43 350 50 60 6 20
Unit A
I D,pulse I AS E AS dv /dt V GS
T C=25 C T C=25 C I D=20 A, R GS=25 I D=50 A, V DS=24 V, di /dt =200 A/s, T j,max=175 C
mJ kV/s V
J-STD20 and JESD22
Rev. 2.0
page 1
2010-02-23
IPD060N03L G IPS060N03L G
Maximum ratings, at T j=25 C, unless otherwise specified Parameter Power dissipation Operating and storage temperature IEC climatic category; DIN IEC 68-1 Symbol Conditions P tot T j, T stg T C=25 C Value 56
IPF060N03L G IPU060N03L G
Unit W C
-55 ... 175 55/175/56
Parameter
Symbol Conditions min.
Values typ. max.
Unit
Thermal characteristics Thermal resistance, junction - case SMD version, device on PCB R thJC R thJA minimal footprint 6 cm cooling area 4) Electrical characteristics, at T j=25 C, unless otherwise specified Static characteristics Drain-source breakdown voltage Gate threshold voltage Zero gate voltage drain current V (BR)DSS V GS=0 V, I D=1 mA V GS(th) I DSS V DS=V GS, I D=250 A V DS=30 V, V GS=0 V, T j=25 C V DS=30 V, V GS=0 V, T j=125 C Gate-source leakage current Drain-source on-state resistance
5)
-
-
2.7 75 50
K/W
30 1 -
0.1
2.2 1
V
A
-
10 10 7.2 5 1.4 67
100 100 9 6 S nA m
I GSS R DS(on)
V GS=20 V, V DS=0 V V GS=4.5 V, I D=30 A V GS=10 V, I D=30 A
Gate resistance Transconductance
2) 3) 4)
RG g fs |V DS|>2|I D|R DS(on)max, I D=30 A
34
See figure 3 for more detailed information See figure 13 for more detailed information
Device on 40 mm x 40 mm x 1.5 mm epoxy PCB FR4 with 6 cm2 (one layer, 70 m thick) copper area for drain connection. PCB is vertical in still air. Measured from drain tab to source pin
5)
Rev. 2.0
page 2
2010-02-23
IPD060N03L G IPS060N03L G
Parameter Symbol Conditions min. Dynamic characteristics Input capacitance Output capacitance Reverse transfer capacitance Turn-on delay time Rise time Turn-off delay time Fall time Gate Charge Characteristics 6) Gate to source charge Gate charge at threshold Gate to drain charge Switching charge Gate charge total Gate plateau voltage Gate charge total Q gs Q g(th) Q gd Q sw Qg V plateau Qg V DD=15 V, I D=30 A, V GS=0 to 10 V V DS=0.1 V, V GS=0 to 4.5 V V DD=15 V, V GS=0 V V DD=15 V, I D=30 A, V GS=0 to 4.5 V 5.6 2.8 2.5 5.3 10.8 3.2 22 C iss C oss Crss t d(on) tr t d(off) tf V DD=15 V, V GS=10 V, I D=30 A, R G=1.6 V GS=0 V, V DS=15 V, f =1 MHz 1700 640 35 5 3 20 3 Values typ.
IPF060N03L G IPU060N03L G
Unit max.
2300 850 52 -
pF
ns
14.4 30
nC
V
Gate charge total, sync. FET Output charge Reverse Diode Diode continuous forward current Diode pulse current Diode forward voltage
Q g(sync) Q oss
-
9.4 17
-
nC
IS I S,pulse V SD
T C=25 C V GS=0 V, I F=30 A, T j=25 C V R=15 V, I F=I S, di F/dt =400 A/s
-
0.88
50 350 1.1
A
V
Reverse recovery charge
Q rr
-
-
10
nC
6)
See figure 16 for gate charge parameter definition
Rev. 2.0
page 3
2010-02-23
IPD060N03L G IPS060N03L G
1 Power dissipation P tot=f(T C) 2 Drain current I D=f(T C); V GS10 V
IPF060N03L G IPU060N03L G
60
60
50
50
40
40
P tot [W]
30
I D [A]
0 50 100 150 200
30
20
20
10
10
0
0 0 50 100 150 200
T C [C]
T C [C]
3 Safe operating area I D=f(V DS); T C=25 C; D =0 parameter: t p
103
limited by on-state resistance
4 Max. transient thermal impedance Z thJC=f(t p) parameter: D =t p/T
10
1 s
102
DC
10 s 0.5 100 s
1
Z thJC [K/W]
0.2 0.1 0.05 0.02
I D [A]
101
1 ms
10 ms
0.1
0.01 single pulse
100
10-1 10-1 100 101 102
0.01
0
0
0
0
0
0
1
10-6
10-5
10-4
10-3
10-2
10-1
100
V DS [V]
t p [s]
Rev. 2.0
page 4
2010-02-23
IPD060N03L G IPS060N03L G
5 Typ. output characteristics I D=f(V DS); T j=25 C parameter: V GS
120
5V 4.5 V
IPF060N03L G IPU060N03L G
6 Typ. drain-source on resistance R DS(on)=f(I D); T j=25 C parameter: V GS
20
100
10 V
3V
16
4V 3.5 V
80
3.2 V
R DS(on) [m]
12
4V
I D [A]
60
3.5 V
8
4.5 V 10 V 5V
40
3.2 V
20
3V 2.8 V
4
11.5 V
0 0 1 2 3
0 0 20 40 60 80 100
V DS [V]
I D [A]
7 Typ. transfer characteristics I D=f(V GS); |V DS|>2|I D|R DS(on)max parameter: T j
100
8 Typ. forward transconductance g fs=f(I D); T j=25 C
100
80
80
60
60
40
g fs [S]
40 20
175 C 25 C
I D [A]
20
0 0 1 2 3 4 5
0 0 20 40 60 80 100
V GS [V]
I D [A]
Rev. 2.0
page 5
2010-02-23
IPD060N03L G IPS060N03L G
9 Drain-source on-state resistance R DS(on)=f(T j); I D=30 A; V GS=10 V 10 Typ. gate threshold voltage V GS(th)=f(T j); V GS=V DS; I D=250 A
IPF060N03L G IPU060N03L G
12
2.5
10 2
8
R DS(on) [m]
98 %
6
typ
V GS(th) [V]
100 140 180
1.5
1
4
2
0.5
0 -60 -20 20 60
0 -60 -20 20 60 100 140 180
T j [C]
T j [C]
11 Typ. capacitances C =f(V DS); V GS=0 V; f =1 MHz
12 Forward characteristics of reverse diode I F=f(V SD) parameter: T j
104
10000
1000
Ciss
103
1000
Coss
100
25 C
175 C, 98%
C [pF]
I F [A]
175 C 25 C, 98%
102
100
10
Crss
101
10
1 5 10 15 20 25 30 0.0 0.5 1.0 1.5 2.0
0
V DS [V]
V SD [V]
Rev. 2.0
page 6
2010-02-23
IPD060N03L G IPS060N03L G
13 Avalanche characteristics I AS=f(t AV); R GS=25 parameter: T j(start)
100
IPF060N03L G IPU060N03L G
14 Typ. gate charge V GS=f(Q gate); I D=30 A pulsed parameter: V DD
12
15 V 6V
24 V
10
150 C
100 C
25 C
8
V GS [V]
100 101 102 103
I AV [A]
10
6
4
2
1 10-1
0 0 5 10 15 20 25 30
t AV [s]
Q gate [nC]
15 Drain-source breakdown voltage V BR(DSS)=f(T j); I D=1 mA
16 Gate charge waveforms
34
V GS
32
Qg
30
V BR(DSS) [V]
28
26
V g s(th)
24
22
Q g(th) Q gs
-60 -20 20 60 100 140 180
Q sw Q gd
Q g ate
20
T j [C]
Rev. 2.0
page 7
2010-02-23
IPD060N03L G IPS060N03L G
Package Outline PG-TO252-3
IPF060N03L G IPU060N03L G
Rev. 2.0
page 8
2010-02-23
IPD060N03L G IPS060N03L G
Package Outline PG-TO251-3-11: Outline PG-TO252-3-23
IPF060N03L G IPU060N03L G
PG-TO251-3-21: Outline
Rev. 2.0
page 9
2010-02-23
IPD060N03L G IPS060N03L G
Package Outline PG-TO251-3-11
IPF060N03L G IPU060N03L G
Rev. 2.0
page 10
2010-02-23
IPD060N03L G IPS060N03L G
Package Outline PG-TO251-3-11: Outline PG-TO251-3
IPF060N03L G IPU060N03L G
PG-TO251-3-21: Outline
Rev. 2.0
page 11
2010-02-23
IPD060N03L G IPS060N03L G
Published by Infineon Technologies AG 81726 Munich, Germany (c) 2008 Infineon Technologies AG All Rights Reserved. Legal Disclaimer The information given in this document shall in no event be regarded as a guarantee of conditions or characteristics. With respect to any examples or hints given herein, any typical values stated herein and/or any information regarding the application of the device, Infineon Technologies hereby disclaims any and all warranties and liabilities of any kind, including without limitation, warranties of non-infringement of intellectual property rights of any third party. Information For further information on technology, delivery terms and conditions and prices, please contact the nearest Infineon Technologies Office (www.infineon.com).
IPF060N03L G IPU060N03L G
Warnings Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure of that life-support device or system or to affect the safety or effectiveness of that device or system. Life support devices or systems are intended to be implanted in the human body or to support and/or maintain and sustain and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may be endangered.
Rev. 2.0
page 12
2010-02-23


▲Up To Search▲   

 
Price & Availability of IPD060N03LG

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X